BETAVIB Overall Quantities Explained

BETAVIB Overall Quantities Explained

Following is an explanation of the 5 overall quantities which come standard in all measurements

VELOCITY

The Betavib “Velocity” value is an RMS value which is an averaged value extracted from a velocity spectrum.

The spectrum from which the RMS Velocity is extracted from is created using the following parameters:

1. Fmin – Fmax: 10Hz – 1kHz

2. 4 avgs @ 70% overlap

3. Hanning window

PEAK

The Betavib “PEAK” value is an acceleration value expressed in gs and is calculated from the long time waveform. It is determined by the equation:

(the highest positive going peak) + (the absolute value of the lowest negative going peak) ÷ 2

RMS

The BetaVib “RMS” value is the overall RMS acceleration value of the long time waveform.

KU

The BetaVib Kurtosis value is a measure of vibration impulsiveness. It is calculated from the long time waveform and is the 4th order quadratic moment, expressed in the equation:

CF

The BetaVib Crest Factor value is taken from the long time waveform and is the ratio of the peak value to the RMS value.

The peak value is determined by averaging together the highest positive going peak with the absolute value of the lowest negative going peak.


    • Related Articles

    • Trend Analysis using VibWorks : Extrapolation

      VibWorks comes embedded with tools helping you to assess quickly the current health of your assets. and that includes a powerful Curve Fitting and Extrapolation method. In order to access this feature, when in Database Management, simply hit the F ...
    • BETAVIB Database Creation Template

      Introduction Use the Following Template in order to have a BETAVIB Engineer create the entire Database hierarchy of your Database. Details This will create the Database with all assets provided in the Template down to the Direction level, making the ...
    • UHDM V5: Reprocess Database Between Two Dates

      The UHDM V5 now includes a feature to retrieve data between two specified dates. This new capability allows users to filter and process measurements taken within a defined date range. To use this feature, follow these steps: 1. Open the Reprocess DB ...
    • SERVER REQUIREMENT V1.3

      1. A windows login account is needed on the domain (if using domains) to login the server. Ex. Betavib_User 2. SQL SERVER 2019 needs to be installed on the database server with SSMS (SQL Server Management Studio). A separate SQL instance is required. ...
    • Exporting a Machine from one Database to another

      What it does The following article will descripe a standalone tool the allows the export of one single Machine with all inherent Data (measurement, Alarms, Fault frequencies...) from one Database to another. This module only works when the source and ...